In the interests of providing unequivocal information about the fire performance of BML Systems and the specific wall assemblies that it can form part of, we are sharing the results from an unprecedented number of tests that have taken place featuring Booth Muirie BML Systems.

All DCLG reports available for download on DCLG web site: https://www.gov.uk/guidance/building-safety-programme#screening-testing-and-wall-cladding-systems-programme

The testing has been carried out in conjunction with Kingspan Insulation UK, Siderise and Mitsubishi. All listed systems have passed the BS8414 test but some are awaiting the official results to be published. Report references will be updated as they are published.

If you have further enquiries please contact us on BS8414@euroclad.co.uk ; you will also find that some of the test results are listed on the BRE website.

Booth Muirie BML100.1

BML100.1/20/Alpolic A2/268/50/84-38/180DS/SR90-30/BW

ASSEMBLY CODE

BML100.1/20/Alpolic A2/268/50/84-38/180DS/SR90-30/BW

BML SYSTEM BML100.1
JOINT SIZE 20mm
PANEL MATERIAL Alpolic A2
CAVITY* 38mm
INSULATION THICKNESS 180mm
InsulatioN TYPE Rockwool Duoslab
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 100.1 (Patent pending) Hidden plate hook-on, 50mm deep ALPOLIC A2 (category 1 in screening tests) cassette panels (20mm joints & 38mm cavity) + 180mm Rockwool Duoslab with Siderise cavity barriers on blockwork wall

Booth Muirie BML100.1

BML100.1/20/Alpolic A2/188/50/84-38/100K15/SR90-30/BW

ASSEMBLY CODE

BML100.1/20/Alpolic A2/188/50/84-38/100K15/SR90-30/BW

BML SYSTEM BML100.1
JOINT SIZE 20mm
PANEL MATERIAL Alpolic A2
CAVITY* 38mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 100.1 (Patent pending) Hidden plate hook-on, 50mm deep ALPOLIC A2 (category 1 in screening tests) cassette panels (20mm joints & 38mm cavity) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on blockwork wall

Booth Muirie BML 100.1

BML100.1/20/Alpolic fr/268/50/84-38/180DS/SR90-30/BW

ASSEMBLY CODE

BML100.1/20/Alpolic fr/268/50/84-38/180DS/SR90-30/BW

BML SYSTEM BML100.1
JOINT SIZE 20mm
PANEL MATERIAL Alpolic/fr
CAVITY* 38mm
INSULATION THICKNESS 180mm
InsulatioN TYPE Rockwool Duoslab
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 100.1 (Patent pending) Hidden plate hook-on, 50mm deep ALPOLIC/fr (category 2 in screening tests) cassette panels (20mm joints & 38mm cavity) + 180mm Rockwool Duoslab with Siderise cavity barriers on blockwork wall

Booth Muirie BML100.1

BML100.1/20/3mm Alu PPC/188/50/85-38/100K15/SR90-30/BW

ASSEMBLY CODE

BML100.1/20/3mm Alu PPC/188/50/85-38/100K15/SR90-30/BW

BML SYSTEM BML100.1
JOINT SIZE 20mm
PANEL MATERIAL 3mm PPC
CAVITY* 38mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 100.1 (Patent pending) Hidden plate hook-on, 50mm deep 3mm PPC Aluminium (A2 Limited combustibility) cassette panels (20mm joints & 38mm cavity) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on blockwork wall

Booth Muirie BML100.1

BML100.1/20/Alpolic fr/188/50/84-38/100K15/SR90-30/BW

ASSEMBLY CODE

BML100.1/20/Alpolic fr/188/50/84-38/100K15/SR90-30/BW

BML SYSTEM BML100.1
JOINT SIZE 20mm
PANEL MATERIAL Alpolic/fr
CAVITY* 38mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 100.1 (Patent pending) Hidden plate hook-on 50mm deep ALPOLIC/fr (category 2 in screening tests) cassette panels (20mm joints & 38mm cavity) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on blockwork wall.

Booth Muirie BML120

BML120/20/Alucopanel A2/125/50/71-25/50FRW/SR90-30/BW

ASSEMBLY CODE

BML120/20/Alucopanel A2/125/50/71-25/50FRW/SR90-30/BW

BML SYSTEM 120
JOINT SIZE 20mm
PANEL MATERIAL Alucopanel A2
CAVITY* 25mm
INSULATION THICKNESS 50mm
InsulatioN TYPE Fujairah Rockwool
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL** Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION
**Block work painted with bitumen

Tested System

Booth Muirie: BML 120 SZ cassette panels formed from Alucopanel A2 ACM (20mm joints, 25mm cavity) + 50mm Fujairah Rockwool insulation with Siderise open state cavity barriers on bitumen painted blockwork wall

Booth Muirie BML400

BML400/20/Alpolic A2/154/4/50-50/100K15/SR90-30/BW

ASSEMBLY CODE

BML400/20/ALPOLIC A2/154/4/50-50/100K15/SR90-30/BW

BML SYSTEM 400
JOINT SIZE 20mm
PANEL MATERIAL Alpolic A2
CAVITY* 50mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (20mm joints, 50mm cavity) ALPOLIC A2 ACM (category 1 in screening tests) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on blockwork wall.

Booth Muirie BML400

BML400/20/Alpolic fr/154/4/50-50/180DS/SR90-30/BW

ASSEMBLY CODE

BML400/20/Alpolic fr/154/4/50-50/180DS/SR90-30/BW

BML SYSTEM 400
JOINT SIZE 20mm
PANEL MATERIAL Alpolic/fr
CAVITY* 50mm
INSULATION THICKNESS 180mm
InsulatioN TYPE Rockwoool Duoslab
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (20mm joints, 50mm cavity) ALPOLIC/fr ACM (category 2 in screening tests) + 180mm Rockwool Duoslab insulation with Siderise cavity barriers on blockwork wall.

Booth Muirie BML400

BML400/4/Alpolic fr/154/4/50-50/100K15/SR90-30/BW

ASSEMBLY CODE

BML400/4/Alpolic fr/154/4/50-50/100K15/SR90-30/BW

BML SYSTEM 400
JOINT SIZE 4mm
PANEL MATERIAL Alpolic/fr
CAVITY* 50mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (4mm joints, 50mm cavity) ALPOLIC/fr ACM (category 2 in screening tests) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on blockwork wall = Pass

Booth Muirie BML400

BML400/20/Alpolic A2/154/4/50-50/100K15/SR90-30/SFS

ASSEMBLY CODE

BML400/20/Alpolic A2/154/4/50-50/100K15/SR90-30/SFS

BML SYSTEM 400
JOINT SIZE 20mm
PANEL MATERIAL Alpolic A2
CAVITY* 50mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL** SFS

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION
**Steel framing system with standard sheathing board and vapour control product

Tested System

Booth Muirie BML 400 Rivet fixed (20mm joints, 50mm cavity) ALPOLIC A2 ACM (category 1 in screening tests) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on SFS wall (with standard sheathing board and vapour control products) = Pass

Booth Muirie BML400

BML400/10/Alpolic fr/154/4/50-50/100K15/SR90-30/BW

ASSEMBLY CODE

BML400/10/Alpolic fr/154/4/50-50/100K15/SR90-30/BW

BML SYSTEM 400
JOINT SIZE 10mm
PANEL MATERIAL Alpolic/fr
CAVITY* 50mm
INSULATION THICKNESS 100mm
InsulatioN TYPE Kingspan Kooltherm K15 Rainscreen Board
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL Blockwork

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (10mm joints, 50mm cavity) ALPOLIC/fr ACM (category 2 in screening tests) + 100mm Kingspan Kooltherm K15 Rainscreen Board with Siderise cavity barriers on blockwork wall = Pass 

Booth Muirie BML400

BML400/10/Alpolic A2/314/4/50-50/100DS+100K15+60K15/SR90-30/SFS

ASSEMBLY CODE

BML400/10/Alpolic A2/314/4/50-50/100DS+100K15+60K15/SR90-30/SFS

BML SYSTEM 400
JOINT SIZE 10mm
PANEL MATERIAL Alpolic A2
CAVITY* 50mm
INSULATION THICKNESS 260mm
InsulatioN TYPE 1 Kingspan Kooltherm K15 Rainscreen Board
INSULATION TYPE 2 Rockwool Duoslab
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL** SFS

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION
** Steel framing system with standard sheathing board and vapour contro product

Tested System

Booth Muirie BML 400 Rivet fixed (10mm joints, 50mm cavity) ALPOLIC A2 ACM (category 1 in screening tests) + 100mm Rockwool duoslab over 160 Kingspan Kooltherm K15 Rainscreen Board (1st layer 60mm 2nd layer 100mm) with Siderise cavity barriers on SFS wall (with standard sheathing board and vapour control products)

Booth Muirie BML400

BML400/10/3mm Alu PPC/103/3/50-50/50DS/SR90-30/136 MetSIP

ASSEMBLY CODE

BML400/10/3mm Alu PPC/103/3/50-50/50DS/SR90-30/136 MetSIP

BML SYSTEM 400
JOINT SIZE 10mm
PANEL MATERIAL 3mm PPC
CAVITY* 50mm
INSULATION THICKNESS 50mm
InsulatioN TYPE Rockwool Duoslab
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL MIB MetSIP Panel

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (10mm joints, 50mm cavity) 3mm PPC Aluminium (A2 Limited combustibility) + 50mm Duoslab with Siderise cavity barriers on 136 MetSIP Standard Panel

Booth Muirie BML400

BML400/10/Alpolic A2/104/4/100-100/SR90-30/SR90-30/136 MetSIP

ASSEMBLY CODE

BML400/10/Alpolic A2/104/4/100-100/SR90-30/SR90-30/136 MetSIP

BML SYSTEM 400
JOINT SIZE 10mm
PANEL MATERIAL Alpolic A2
CAVITY* 100mm
INSULATION THICKNESS N/A
InsulatioN TYPE N/A
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL** MIB MetSIP Panel

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (10mm joints, 100mm cavity) ALPOLIC A2 ACM (category 1 in screening tests) with Siderise cavity barriers on 136 MetSIP standard panel

Booth Muirie BML400

BML400/10/3mm Alu PPC/103/3/100-100/SR90-30/SR90-30/136 MetSIPX

ASSEMBLY CODE

BML400/10/3mm Alu PPC/103/3/100-100/SR90-30/SR90-30/136 MetSIPX

BML SYSTEM 400
JOINT SIZE 10mm
PANEL MATERIAL 3mm PPC
CAVITY* 100mm
INSULATION THICKNESS N/A
InsulatioN TYPE N/A
HORIZONTAL CAVITY BARRIERS Siderise 90/30
VERTICAL CAVITY BARRIERS Siderise 90/30
BACKING WALL** MIB MetSIP Panel

*REDUCED CAVITY DEPTH AT HORIZONTAL JOINT POSITION

Tested System

Booth Muirie BML 400 Rivet fixed (10mm joints, 100mm cavity) 3mm PPC Aluminium (A2 Limited combustibility) with Siderise cavity barriers on 136 MetSIP X-Panel

BS 8414 TESTED SYSTEMS

Project Enquiry form